D-SUB Connector,CABLE ASSEMBLIES,
Coaxial Cable > Tools,Anti-ant and mouse destroy PVC jacket available,
 

Control Cable › With Shield Foil + Braid
› IB... Multiconductors › IB...(P) Multipairs › IBI...(P) Individual Foil


With Shield Foil + Braid › IB... Multiconductors
Product Description UL subject 13 type CL2, CL3
NEC articles 725-38 (b) (1)
105°C, 300, 600 Volt
Conductor Fine stranded concentric bare copper
Insulation 105°C PVC optional PE, XLPE, PP
Shield 100% coverage, aluminium polyester foil shield and 85% of copper braided
Drain Wire 7 strands tinned copper
Jacket Black sunlight resistant PVC
Application For process control and instrumentation. Passes UL type
CL2, CL3 vertical tray flame test. Installed in cable trays, raceways, conduit or aerial.
UL File No.: E125840 , CSA File No.: LL80602 .
( UL type CL2 , CL3 and CSA type AWM FT4 Listed )

Part No Description Brochure
IB035xx 22 AWG, 0.35 sqmm. DCR 55.4 ohm/km
IB050xx 20 AWG, 0.50 sqmm. DCR 34.4 ohm/km
IB075xx 18 AWG, 0.75 sqmm. DCR 21.9 ohm/km
IB100xx 17 AWG, 1.00 sqmm. DCR 17.4 ohm/km
IB125xx 16 AWG, 1.25 sqmm. DCR 14.3 ohm/km
IB150xx 15 AWG, 1.50 sqmm. DCR 10.8 ohm/km
IB250xx 13 AWG, 2.50 sqmm. DCR 6.82 ohm/km
IB400xx 11 AWG,4.0 sqmm. DCR 4.33 Ohm/km
IB600xx 9 AWG, 6.0 sqmm DCR 2.7 Ohm/km


With Shield Foil + Braid › IB...(P) Multipairs
Product Description UL subject 13 type CL2, CL3
NEC articles 725-38 (b) (1)
105°C, 300, 600 Volt
Conductor Fine stranded concentric bare copper
Insulation 105°C PVC optional PE, XLPE, PP
Construction Twisted pairs construction, traids and quads twisted also available
Shield 100% coverage aluminium polyester foil shield and 85% of copper braided
Drain Wire 7 strands tinned copper
Jacket Black sunlight resistant PVC
Application For process control and instrumentation. Passes UL type
CL2, CL3 vertical tray flame test. Installed in cable trays, raceways, conduit or aerial.
UL File No.: E125840 , CSA File No.: LL80602 .
( UL type CL2 , CL3 and CSA type AWM FT4 Listed )

Part No Description Brochure
IB050xxP 20 AWG 0.50sqmm. DCR 34.4 Ohm/km Multipairs
IB075xxP 18 AWG, 0.75 sqmm. DCR 21.9 Ohm/km Multipairs
IB125xxP 16 AWG, 1.25 sqmm. DCR 14.3 Ohm/km Multipairs


With Shield Foil + Braid › IBI...(P) Individual Foil
Product Description UL subject 13 type CL2, CL3
NEC articles 725-38 (b) (1)
105°C, 300, 600 Volt
Conductor Fine stranded concentric bare copper
Insulation 105°C PVC optional PE, XLPE, PP
Construction Twisted pairs construction with individually foil each pairs, traids and quads twisted also available
Shield 100% coverage aluminium polyester foil shield and 85% of copper braided
Drain Wire 7 strands tinned copper
Jacket Black sunlight resistant PVC
Application For process control and instrumentation. Passes UL type
CL2, CL3 vertical tray flame test. Installed in cable trays, raceways, conduit or aerial.
UL File No.: E125840 , CSA File No.: LL80602 .
( UL type CL2 , CL3 and CSA type AWM FT4 Listed )

Part No Description Brochure
IBI050xxP 20 AWG, 0.50 sqmm. DCR 34.4 ohm/km Multipairs
IBI075xxP 18 AWG, 0.75 sqmm. DCR 21.9 ohm/km Multipairs
IBI125xxP 16 AWG, 1.25 sqmm. DCR 13.7 ohm/km Multipairs