Control Cable › Special Cable


Special Cable › HEC... Flat type Elevator control cable

  • Detail
  • Specification
Product Description
UL subject 13 type CL2, CL3
NEC articles 725-38 (b) (1)
105°C, 300, 600 Volt
Conductor
Fine stranded concentric bare copper
Insulation
105°C PVC optional PE, XLPE, PP
Shield
100% coverage, aluminium polyester foil shield and 85% of copper braided
Drain Wire
7 strands tinned copper
Jacket
Black sunlight resistant PVC
Application
For process control and instrumentation. Passes UL type CL2, CL3 vertical tray flame test. Installed in cable trays, raceways, conduit or aerial. UL File No.: E125840 , CSA File No.: LL80602 . ( UL type CL2 , CL3 and CSA type AWM FT4 Listed )
Part No Description Brochure
HEC075xx 18 AWG, 0.75 sqmm. DCR 21.9 ohm/km
HEC125xx 16 AWG, 1.25 sqmm. DCR 14.3 ohm/km


Special Cable › HECR... Self support Crane control cable

  • Detail
  • Specification
Conductor:
Fine stranded copper conductor
Insulation:
Color coded PVC insulation Core cabled under fabric tape
Jacket
PVC jacket with self supporting steel wire
Rated
Temp. 75°C. Voltage 600 V. Pass UL VW-1 and CSA FT1 vertical flame test
Application
For vertical switch control of crane or electrical equipment
Part No Description Brochure
HECR1.25xx + Sling 1.25 MM2 Flexible Control w.sling

HECR1.50xx + 2 Sling 1.50 MM2 Flexible Control w.sling (2)


Special Cable › IPS... Multiconductors with Steel wire Braided Double sheath

  • Detail
  • Specification
Product Description
UL subject 13 type CL2 , CL3
NEC articles 725-38 (b) (1)
105°C , 300, 600 Volt
Conductor:
Fine stranded concentric bare copper
Insulation:
105°C PVC optional PE, XLPE, PP
Construction
Twisted pairs construction, traids and quads twisted also available
Protection
IPC...Copper or IPA...aluminium or IPS...galvanized steel wire braided
Jacket
Inner PVC jacket plus PVC outer jacket
Application
For process control and instrumentation in heavy duty area. Oasses UL type CL2, CL3 vertical tray flame test. Installed in cable trays, receways, conduit or aerial.
Part No Description Brochure
IPx050xx 20 AWG, 0.50 sqmm. DCR 34.4 ohm/km
IPx075xx 18 AWG, 0.75 sqmm. DCR 21.9 ohm/km
IPx100xx 17 AWG, 1.00 sqmm. DCR 17.4 ohm/km
IPx150xx 15 AWG, 1.50 sqmm. DCR 10.8 ohm/km
[ xx : Cores ]

Special Cable › UL 1007 CSA TR-64 ( 300V )

  • Detail
  • Specification
Conductor
Solid or Standed concentric tinned copper
Insulation
Color coded PVC insulation
Rated
Temp. 80°C Voltage 300 V. Pass UL VW-1 and CSA FT1 vertical flame test Available colors in red, yellow, blue, white, black, green, brown, orange, purple.
Application
For general purpose internal wiring of electronic and electrical equipment.
Part No Description Brochure
UL1007xx 16 AWG - 26 AWG


Special Cable › UL 1015 CSA TEW ( 600 V )

  • Detail
  • Specification
Conductor
Standed concentric tinned copper
Insulation
Color coded PVC insulation
Rated
Temp. 105°C Voltage 600 V. Pass UL VW-1 and CSA FT1 vertical flame test Available colors in red, yellow, blue, white, black, green, brown, orange, purple.
Application
For general purpose internal wiring of electronic and electrical equipment.
Part No Description Brochure
UL1015xx 6 AWG - 26 AWG


Special Cable › Tinned Copper Flat Braid

  • Detail
  • Specification
Conductor
Fine stranded woven tinned copper braid Rolled flat to specific width Each strand meets requirement of ASTM B-33
Application
For general purpose of ground wiring.
Part No Description Brochure
UL1007xx 16 AWG - 26 AWG